Close-coupled, chilled water cooling for medium to large data centers
Includes: Installation Guide, Operations and Maintenance Manual
Active Airflow Control
Monitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.
Dew point monitoring
Prevents condensation from forming inside the enclosure by dissuading access when the external dew point is above supply air temperature.
Hot swappable fans
Allows system to remain operational if a fan replacement is required.
Leak detection
Notifies user in the event of a water leak within the coiling unit.
Top and bottom chilled water connections
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Washable filters
Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.
InRow Chilled Water Cooling Features & Benefits
Manageability
Building management system integration
Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Microprocessor controller
Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Real-Time Capacity Monitoring
Real-time display of current and available cooling.
Serviceability
Easy service access
Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
Agility
Casters
Provides flexibility to move the unit to wherever cooling is required.
Modular design
Modular design provides scalable solutions to add cooling as demand increases.
Scaleable densities
Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
Total Cost of Ownership
Variable speed fans
Variable speed fans reduce energy consumption during off-peak cooling periods.
Row-based architecture
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
Availability
Predictable cooling
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Dual A-B power inputs
Draws power from the UPS for power protection with dual feeds for redundancy.
Rack inlet control
Rack inlet control guarantees inlet temperature to IT equipment.
Top and bottom chilled water connections
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Active response controls
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Input
Nominal Input Voltage
200V
Input frequency
50/60 Hz
Input Connections
Hard Wire 3-wire
Number of Power Cords
2
Power Feeds
2.0
Input Power
1900.0Watts
Maximum Overcurrent Protection
15.0A
Minimum Circuit Amp Capacity
15.0
Communications & Management
Control panel
Multi-function LCD status and control console
Audible Alarm
Audible and visible alarms prioritized by severity
Physical
Maximum Height
78.39inches (1991mm, 199.1CM)
Maximum Width
11.8inches (300mm, 30.0CM)
Maximum Depth
43.11inches (1095mm, 109.5CM)
Rack Height
42U
Net Weight
462.97lbs. (210.0KG)
Shipping weight
485.02lbs. (220.0KG)
Shipping Height
83.39inches (2118mm, 211.8CM)
Shipping Width
29.38inches (746mm, 74.6CM)
Shipping Depth
44.75inches (1137mm, 113.7CM)
Color
Black
Units per Pallet
1.0
Conformance
Approvals
C-tick, CE, EN 55022 Class A, EN 55024, EN 60950, GOST, IEC 60950, IEC 61000-3-2, IEC 61000-3-3, MEA, VDE