InRow RC, 300mm, Chilled Water, 208-230V, 50/60Hz – HT | ACRC301H

  • Close-coupled, chilled water cooling for medium to large data centers

  • Includes: Installation Guide, Operations and Maintenance Manual

Produk ini saat ini kehabisan stok dan tidak tersedia.

ACRC301H Features

InRow RC, 300mm, Chilled Water, 208-230V, 50/60Hz - HT
Close-coupled, chilled water cooling for medium to large data centers
Includes: Installation Guide, Operations and Maintenance Manual
  • Active Airflow Control
    Monitors and actively adjust cooling unit airflow in containment systems, while providing visibility to effective cooling to critical IT equipment.
  • Dew point monitoring
    Prevents condensation from forming inside the enclosure by dissuading access when the external dew point is above supply air temperature.
  • Hot swappable fans
    Allows system to remain operational if a fan replacement is required.
  • Leak detection
    Notifies user in the event of a water leak within the coiling unit.
  • Top and bottom chilled water connections
    Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
  • Washable filters
    Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.

InRow Chilled Water Cooling Features & Benefits

Manageability

Building management system integration

Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Microprocessor controller

Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Real-Time Capacity Monitoring

Real-time display of current and available cooling.

Serviceability

Easy service access

Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Agility

Casters

Provides flexibility to move the unit to wherever cooling is required.
Modular design

Modular design provides scalable solutions to add cooling as demand increases.
Scaleable densities

Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.

Total Cost of Ownership

Variable speed fans

Variable speed fans reduce energy consumption during off-peak cooling periods.
Row-based architecture

Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

Availability

Predictable cooling

Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Dual A-B power inputs

Draws power from the UPS for power protection with dual feeds for redundancy.
Rack inlet control

Rack inlet control guarantees inlet temperature to IT equipment.
Top and bottom chilled water connections

Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Active response controls

Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

Input

Nominal Input Voltage

200V
Input frequency

50/60 Hz
Input Connections

Hard Wire 3-wire
Number of Power Cords

2
Power Feeds

2.0
Input Power

1900.0Watts
Maximum Overcurrent Protection

15.0A
Minimum Circuit Amp Capacity

15.0

Communications & Management

Control panel

Multi-function LCD status and control console
Audible Alarm

Audible and visible alarms prioritized by severity

Physical

Maximum Height

78.39inches (1991mm, 199.1CM)
Maximum Width

11.8inches (300mm, 30.0CM)
Maximum Depth

43.11inches (1095mm, 109.5CM)
Rack Height

42U
Net Weight

462.97lbs. (210.0KG)
Shipping weight

485.02lbs. (220.0KG)
Shipping Height

83.39inches (2118mm, 211.8CM)
Shipping Width

29.38inches (746mm, 74.6CM)
Shipping Depth

44.75inches (1137mm, 113.7CM)
Color

Black
Units per Pallet

1.0

Conformance

Approvals

C-tick, CE, EN 55022 Class A, EN 55024, EN 60950, GOST, IEC 60950, IEC 61000-3-2, IEC 61000-3-3, MEA, VDE
Standard warranty

1 year (parts only)

Sustainable Offer Status

RoHS

Compliant
REACH

REACH: Contains No SVHCs
Proposition 65 Warning

Available in Documentation tab

General

Air Discharge Patterns

Horizontal
Air Flow

4200.0CFM (1982.18lps)
Intake Air

Rear Return
Minimum Water Inlet Temperature

45.0 °F (7.0 °C)
TOP