Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Top Distribution Piping | ACFD12-T

  • Air ventilation for wiring closets

  • Includes: Installation Guide

Produk ini saat ini kehabisan stok dan tidak tersedia.

ACFD12-T Features

Cooling Distribution Unit 12 Circuit, Bottom/Top Mains, Top Distribution Piping
Close-coupled, chilled water cooling for medium to large data centers
Includes: Installation guide
  • Coolant balancing
    Provides a central point for fluid balancing.
  • Front service access
    The system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side.
  • Isolated cooling circuit
    A separate, isolated section which houses all cooling components minimizes the risk of water contacting installed IT equipment in the unlikely event of a leak.
  • Top and bottom chilled water connections
    Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.

InRow Chilled Water Cooling Features & Benefits

Manageability

Building management system integration

Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Microprocessor controller

Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Real-Time Capacity Monitoring

Real-time display of current and available cooling.

Serviceability

Easy service access

Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.

Agility

Casters

Provides flexibility to move the unit to wherever cooling is required.
Modular design

Modular design provides scalable solutions to add cooling as demand increases.
Scaleable densities

Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.

Total Cost of Ownership

Variable speed fans

Variable speed fans reduce energy consumption during off-peak cooling periods.
Row-based architecture

Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

Availability

Predictable cooling

Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Dual A-B power inputs

Draws power from the UPS for power protection with dual feeds for redundancy.
Rack inlet control

Rack inlet control guarantees inlet temperature to IT equipment.
Top and bottom chilled water connections

Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Active response controls

Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

Physical

Maximum Height

78.4inches (1991mm, 199.1CM)
Maximum Width

42.14inches (1070mm, 107.0CM)
Maximum Depth

29.54inches (750mm, 75.0CM)
Net Weight

593.0lbs. (269.56KG)
Shipping weight

692.0lbs. (314.56KG)
Shipping Height

85.0inches (2159mm, 215.9CM)
Shipping Width

48.0inches (1219mm, 121.9CM)
Shipping Depth

35.0inches (889mm, 88.9CM)
Color

Black
Units per Pallet

1.0

Conformance

Approvals

MEA
Standard warranty

1 year (parts only)

Sustainable Offer Status

Proposition 65 Warning

Available in Documentation tab